The Fast Read-out System for the MAPMTs of COMPASS RICH- 1

Abbon, P. and others

Keywords

No keywords

Abstract

A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultipliers. The data are digitized on the frontend boards and transferred via optical links to the readout system. The read-out electronics system is described in detail together with its measured performances.

Information

Published
2008 as article
Nucl. Instrum. Meth., A595 - page(s): 204-207
Contact
Prof. Dr. Stephan Paul
Type
experimental work
Links
pdf
spires
www-library.desy.de/…
Related to the research area(s):
D
e-Print
0712.1964

Technische Universitaet Muenchen
Exzellenzcluster Universe

Boltzmannstr. 2
D-85748 Garching

Tel. + 49 89 35831 - 7100
Fax + 49 89 3299 - 4002
info@universe-cluster.de