Response of the CALICE Si-W Electromagnetic Calorimeter Physics Prototype to Electrons

Adloff, C. and others

Keywords

No keywords

Abstract

A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2. Data were collected with electron beams in the energy range 6 to 45 GeV. The analysis described in this paper focuses on electromagnetic shower reconstruction and characterises the ECAL response to electrons in terms of energy resolution and linearity. The detector is linear to within approximately the 1% level and has a relative energy resolution of (16.6 _s16- 0.1)/ sqrt{E(GeV}) _s16 1.1 _s16- 0.1 (%). The spatial uniformity and the time stability of the ECAL are also addressed.

Information

Published
2008 as article
Contact
Dr. Frank Simon
Type
experimental work
Links
pdf
spires
www-library.desy.de/…
Related to the research area(s):